| SPECIFICATIONS |
WATERBUGS |
| MODEL #'s |
WB-200/WB-800 WB-350/WB-100 |
MODEL |
| CONSOLE
SIZE PART # TO ORDER |
5"x2.44"x1.25" (WB-200) 6.55" x 4.70" x 1" (WB-800)
PN #1043 / PN #M-001-0005 |
5"x2.44"x1.25" PN #1047/ 1046 |
PROBE
SIZE (standard - ALL EXCEPT WB-100)
PART # TO ORDER PROBE
SIZE (supervised - FOR WB-800 ONLY)
PART # TO ORDER |
2" X 3" X .88" PN #1040 2" X 3"
X .88" PN # M-001-0006 |
| PROBE SIZE (under
carpet) (ALL EXCEPT WB-100) PART
# TO ORDER |
2" x 3" x .18" PN #1041 |
| POWER REQUIREMENTS* |
12, 24 VDC
12, 24 VAC
*Jumper select able |
9 VDC via alkaline battery
(not included) |
| CURRENT DRAW RESTING STATE |
38 mA @ 1224 VDC(WB-200)
75 mA @ 1224 VDC (WB-800)
100 mA RMS @ 1224 VAC (WB-200)
200 mA RMS @ 1224 VAC (WB-800) |
1.8 microamps |
| CURRENT DRAW ALARM CONDITION |
5 mA @ 12 24 VDC (WB-200)
125 mA at 12 24 VDC )WB-800)
13.5 mA (WB-200) &
330 mA (WB-800) @ 12,24 VAC |
380 microamps |
| SENSITIVITY |
Will not alarm due to high humidity
or condensation |
| APPROXIMATE BATTERY
LIFE |
N/A |
1 year |
| OPERATING TEMPERATURE |
Control & Probe 32° to 140°F
(0° to 60°C) |
| OUTPUTS |
Form "C" contacts (SPDT) 1 Amp @ 24 VAC resistive
1 Amp @ 30 VDC resistive |
Open collector Max. to tripline: 30VDC Max.
collector: 25 mA |
| RECOMMENDED MAXIMUM PROBES
PER CONSOLE |
1 - 2 Probes (Max. 200 feet) 3 &
Up Probes (Max. 100 feet per probe) |
| RECOMMENDED MAXIMUM PROBES
PER CONSOLE |
(6) Six (WB-200 & WB-350) (8)
Eight (WB-800 in supervised mode) (16) Sixteen
(WB-800 in unsupervised mode) |